Sun and Thermal Control Glass

Sun and Thermal Control Glass

These are single, double and triple layer glasses produced by magnetron coating method on flat glass and project-based low-iron glasses. They contain different color tones due to the coating containing silver.

There are risks of thermal breakage due to the solar control function. For this reason, it is recommended to use fully tempered or heat strengthened glass. If the tempering process is not preferred, thermal breakage risk calculation should be made.


Day LightSolar EnergyU Value
(EN 410)(EN 410)(EN 673) W/m²K
TransmittanceReflectance (out)SolarShading AirArgon
ProducerProductCombination(%)(%)FactorCoefficient
AGC Energy 72/38 T6 (#2) + 16 + 472130,380,441,21,0
AGC Stopray Vision 62/33 T6 (#2) + 16 + 461150,330,381,31,0
Guardian Sunguard HP Neutral 60/406 (#2) + 16 + 460250,400,461,31,1
Guardian Sunguard SN 70/35 HT6 (#2) + 16 + 470140,350,401,21,0
Guardian Sunguard SNX 60 HT 6 (#2) + 16 + 460130,290,341,21,0
Saint GobainCool-Lite SKN 183 II6 (#2) + 16 + 475120,400,461,21,0
Saint GobainCool-Lite Extreme 70-33 II6 (#2) + 16 + 470110.330,381,21,0
ŞişecamTemperable Solar Low-E Neutral 50/336 (#2) + 16 + 449310,330,381,31,1
ŞişecamTemperable Solar Low-E Neutral 50/256 (#2) + 16 + 450150,250,291,21,0
ŞişecamTemperable Solar Low-E Neutral 58/326 (#2) + 16 + 458210,320,381,31,1
ŞişecamTemperable Solar Low-E Neutral 70/406 (#2) + 16 + 469110,400,461,31,1
VitroSolarban 72 VT6 (#2) + 16 + 467130,300,341,21,1
VitroSolarban 90 VT6 (#2) + 16 + 451120,230,261,21,1
Translucency:The percentage of light that passes through the glass.
Daylight Reflection:The percentage of light that is reflected by the glass.
Solar Energy Total Translucency:The percentage of the total sun heat that affects the indoors.
Shade Coefficient:Comparison of the total translucency of solar energy with 3 mm colourless glass.
Heat Conductivity Coefficient (U value)The measure of the heat escaping outdoors.